Rekacipta Inovasi ITB

Vent-I (Ventilator Indonesia) CPAP & HFNC

Vent-I (Ventilator Indonesia) is a nationally recognized technology that is used to assist the breathing of patients who experience shortness of breath but are still able to breathe independently.

Vent-I Essential 3.5 Ventilator

  • Ventilator type non invasive dual function CPAP (Continues Positive Airway Pressure) & HFNC (High Flow Nasal Cannula).
  • As CPAP serves to provide a high flow oxygen supply and provide PEEP (positive end expiratory pressure) pressure to patients aimed at maintaining lung function.
  • As HFNC functions to provide a high flow oxygen supply with an oxygen fraction (FI02) of 60% – 98%.
  • The use of this tool is intended to assist the breathing of patients who experience shortness of breath but are still able to breathe independently.

Unit Specifications

  1. Product Name: Vent-I Essential 3.5 CPAP-HFNC Ventilator
  2. PEEP pressure setting range: 5 cmH2O, 10 cmH2O, or 15 cmH2O
  3. O2 gas input pressure: 2 – 4 bar (according to O2 gas regulator specifications)
  4. Oxygen content FiO2: 52% to 55% (CPAP mode) and 40% to 100% (HFNC mode)
  5. Mixed air flow rate CPAP function: 33 to 37 Liters per minute (auto mode) & max 60 liters per minute (manual mode) HFNC function: 30 – 60 liters per minute
  6. Noise level: < 70 dB
  7. PEEP mechanism: Hydrostatic Air
  8. Total pressure and flow rate control: Microcomputer Control System
  9. LCD Pressure Display: LCD with size 76 x 26 mm
  10. Blower Specifications: Centrifugal Fan 0-7 Kpa
  11. Air Filter: H13 HEPA Filter
  12. Power Consumption: Max 80 VA
  13. Current Consumption: Max 0.35 Ampere
  14. Pressure alarm (audio): Alarm sounds when the pressure is more than 20 cmH2O.
  15. Power Supply: AC 220-240 V; 50/60 Hz
  16. Power Source Voltage: AC (230+/-10%) V
  17. Power Source Frequency: 50/60 Hz
  18. Unit Dimensions (mm) (P x L x T): 181 x 273 x 234
  19. Net Weight: 3.2 kg

Heated Humidifier Specifications

  1. Product Name: VENT-I Heated Humidifier
  2. Temperature setting range:
    • Room temperature 20 ° C, the temperature at the outlet of the Humidifier Chamber is approximately 8 ° C. hotter than the temperature in the Mask.
    • Room temperature 25 ° C, the temperature at the outlet of the Humidifier Chamber is approximately 6 ° C hotter than the temperature in the Mask.
    • Room temperature 30 ° C, the temperature at the outlet of the 5 ° C Chamber Humidifier is approximately 5 ° C hotter than the temperature in the Mask.
    • compared to the temperature at the Mask.
  3. Installation Alarm: The alarm sounds and the LED lights up in red if the Chamber Humidifier installation and the temperature sensor at the outlet of the Chamber Humidifier are not installed correctly.
  4. Heated humidifier mechanism: Heating water with a separate Chamber Humidifier using a slab-shaped heater.
  5. Power Consumption: Max 330 VA
  6. Power Supply : AC 220-240 V; 50/60 Hz
  7. Unit Dimensions (mm) (P x L x T): 155 x 174 x 96
  8. Net Weight: 0.9 kg

NIE (Circulation Permit Number): KEMENKES RI AKD 20403120615

Distributor: PT.Gobel Dharma Nusantara

Manufacturer: PT PHC Indonesia

Scroll to Top